Shenzhen Meiri Purification Technology Co., Ltd.

MAKE ROOM JUST HYGIENIC

Manufacturer from China
Verified Supplier
2 Years
Home / Products / FFU Cleanroom /

BFU Bottom-Access FFU| Easy-Maintenance HEPA System for Hospital ORs & Microelectronics Labs | Compact & Vibration-Free Design

Contact Now
Shenzhen Meiri Purification Technology Co., Ltd.
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MrNeal Liao
Contact Now

BFU Bottom-Access FFU| Easy-Maintenance HEPA System for Hospital ORs & Microelectronics Labs | Compact & Vibration-Free Design

Ask Latest Price
Video Channel
Brand Name :MRJH
Model Number :BFU bottom detachable FFU 620X620X350
Certification :ISO 14644-1,ISO 9001,CE
Place of Origin :Guangdong, China
MOQ :1
Price :Detailed communication
Delivery Time :7-15 days
custom made :support
Contact Now

Add to Cart

Find Similar Videos
View Product Description

BFU Bottom-Access FFU| Easy-Maintenance HEPA System for Hospital ORs & Microelectronics Labs | Compact & Vibration-Free Design

The BFU Bottom-Access FFU 620X620X350 revolutionizes cleanroom maintenance with its ground-breaking bottom-access panel design, specifically engineered for high-frequency filter replacement environments like hospital operating rooms, microelectronics assembly lines, and ISO Class 4-6 clean zones. Its 620x620x350mm compact footprint integrates seamlessly into space-constrained ceilings while delivering 360 m³/h airflow with ultra-low turbulence.

Parameter Name

Value

Material

Box: Galvanized aluminum plate; Diffuser: Baked-paint cold plate

Fan System

MRJH® motor + metal impeller

Filtration

Aluminum frame HEPA filter (570×570×69), Efficiency: 99.99% @0.3μm (H13)

Air Speed

0.45–0.75 m/s ±3% (three-speed adjustable)

Noise Level

46–55 dB ±5 dB (static test 1.5m below filter)

Power Supply

220V/50Hz, Rated Power: 150W–190W ±5W

Vibration

≤5μm peak

Flange Connection

Optional D=25mm

Opening Size

Color steel plate: 625×625 mm

size

1175X1175X215(mm)

Certifications

ISO 14644-1,ISO 9001,CE

Key Features

1. Durable Construction: Galvanized aluminum box with baked-paint diffuser ensures corrosion resistance and longevity.

2. Efficient Fan System: MRJH® motor paired with a metal impeller delivers stable airflow and ultra-low noise.

3. Precision Airflow Control: Three-speed adjustable wind speed (0.45–0.75 m/s ±3%) for flexible cleanroom requirements.

4. H13 Filtration: Non-partition HEPA filter achieves 99.99% efficiency at 0.3μm particles.

5. Bottom-Detachable Design: Simplifies maintenance and filter replacement.

6. Optional Connectivity: Supports flange connections (D=25mm) and group control modules for system integration.

7. Low Noise: Engineered for 46–55 dB (±5 dB) operation at 1.5m below the filter.

Application Scenarios

Cleanroom air purification in pharmaceutical, electronics, and biotechnology facilities.
Manufacturing zones requiring ISO-certified H13 filtration with precise airflow control.
Facilities needing modular installation (flange compatibility) and easy maintenance.

BFU Bottom-Access FFU| Easy-Maintenance HEPA System for Hospital ORs & Microelectronics Labs | Compact & Vibration-Free Design

BFU Bottom-Access FFU| Easy-Maintenance HEPA System for Hospital ORs & Microelectronics Labs | Compact & Vibration-Free Design

BFU Bottom-Access FFU| Easy-Maintenance HEPA System for Hospital ORs & Microelectronics Labs | Compact & Vibration-Free Design


BFU Bottom-Access FFU| Easy-Maintenance HEPA System for Hospital ORs & Microelectronics Labs | Compact & Vibration-Free Design

BFU Bottom-Access FFU| Easy-Maintenance HEPA System for Hospital ORs & Microelectronics Labs | Compact & Vibration-Free Design

BFU Bottom-Access FFU| Easy-Maintenance HEPA System for Hospital ORs & Microelectronics Labs | Compact & Vibration-Free Design

BFU Bottom-Access FFU| Easy-Maintenance HEPA System for Hospital ORs & Microelectronics Labs | Compact & Vibration-Free Design

BFU Bottom-Access FFU| Easy-Maintenance HEPA System for Hospital ORs & Microelectronics Labs | Compact & Vibration-Free Design

BFU Bottom-Access FFU| Easy-Maintenance HEPA System for Hospital ORs & Microelectronics Labs | Compact & Vibration-Free Design

BFU Bottom-Access FFU| Easy-Maintenance HEPA System for Hospital ORs & Microelectronics Labs | Compact & Vibration-Free Design

FAQ :
1. How does the bottom-access design simplify HEPA filter maintenance in sterile environments like ORs?
The tool-free, bottom-loading mechanism allows single-person filter replacement without dismantling the unit or disrupting laminar airflow – critical for maintaining ISO Class 5 conditions during surgeries or microelectronics production.
2. What makes this FFU suitable for vibration-sensitive applications like semiconductor metrology?
Featuring a brushless DC motor with G2.5 dynamic balance and <3µm vibration levels, it eliminates interference with sensitive equipment (e.g., electron microscopes or lithography tools) while operating at <50dB.
3. Can the compact 575x575x250mm frame integrate with existing cleanroom grids?
Yes, it supports:
Drop-in installation for standard 2'x2' T-bar ceilings
Flange-less sealing to prevent particle leakage
Optional 1200x600mm adapters for ISO 14644-1 recertification

Inquiry Cart 0