
Add to Cart
Glass Cleanroom Wardrobe | H13 HEPA 99.995% & EN 1822 | 25-Person ISO 14644 Storage
Glass-fronted cleanroom wardrobe with H13 filtration system, designed for particle-controlled environments requiring hygienic garment storage. Ideal for pharmaceutical facilities, semiconductor cleanrooms, and biotech labs with ISO 14644 compliance needs.
Parameter Name | Value |
Main Frame Material | 30×30×1.0mm SUS304 Stainless Steel |
Back/Base Panels | 304 Stainless Steel Plate |
FFU Configuration | 1175×575×300mm Al-Zn Coated Steel |
HEPA Filter | 1170×570×69mm H13 (99.995%@0.3μm) |
External Dimensions | W800×D600×H2160mm |
Capacity | 25-Person Garment & Footwear Storage |
Key Features
1. Cleanroom-Grade Filtration
Integrated FFU system delivers ISO Class 5 airflow (0.45m/s ±20%) with H13 HEPA filtration (EN 1822 certified).
Automatic filter life monitoring via pressure differential sensor (±5Pa accuracy).
2. Contamination Control Design
Drape-front upper doors minimize particle generation during access (tested per IEST-RP-CC018).
Sealed lower cabinets with key locks prevent cross-contamination between clean/dirty zones.
3. Ergonomic Configuration
Height-adjustable feet (range ±15mm) compensate for uneven floors in industrial settings.
600mm depth accommodates full-body cleanroom suits (EN 13034 Type 4-6 compliant).
4. Maintenance Optimization
Removable perforated shelves (2mm apertures) enable 360° airflow for garment drying.
Electropolished surfaces (Ra ≤0.8μm per ASTM B912) resist microbial adhesion.
5. Safety Compliance
Emergency release mechanism on locked compartments (meets ANSI/BHMA A156.10).
Fire-rated glass (60-minute integrity per BS 476-22) in upper observation panels.
Application Scenarios
Pharmaceutical filling lines: GMP-compliant storage for sterile gowning
Lithography cleanrooms: Particle-free uniform storage for EUV wafer processing
Vaccine research labs: Biosafety Level 2 (BSL-2) garment containment
Food packaging facilities: HACCP-certified hygiene zone transitions
Aerospace assembly: FOD-controlled workwear management
FAQ 1:
Q: Does the glass door design affect HEPA airflow integrity during access?
A: Motorized drape seal maintains ISO Class 5 conditions (≤5 Pa pressure loss) when opening.
FAQ 2:
Q: How often to replace H13 filters in high-particulate semiconductor environments?
A: 18-24 month lifespan with 800Pa max resistance, monitored via digital manometer ports.
FAQ 3:
Q: Can it integrate with existing cleanroom pass-through systems?
A: Yes, optional RFID sync with airlock controls and 575×575mm standard pass-through compatibility.